Visual Fault Locator Netpeppers Gmbh

Browse technical resources about fiber optic cables and interconnect systems for critical infrastructure networks – smart city, rail, mining, ports, petrochemical, broadcasting, security, medical, c...

  • 10kV busbar overvoltage fault

    10kV busbar overvoltage fault

    Circuit Breaker Failure to Operate or Maloperation: Check the energy storage mechanism, closing/tripping coils, auxiliary switches, and secondary circuits. but there was no issue in input voltage frequency or battery voltage or any issue. Kindly tell me the reason and solution. Thanks Engr Raja Haroon Rasheed Posted: ‎2020-07-03 01:39 PM. Last Modified:. The DC bus overvoltage fault, also called a DC bus error or simply an overvoltage fault, is among the most common faults on an AC variable frequency drive. Because it's so common, some newer drives try to assist with locating the issue by providing more information about what the drive was doing. What's really causing your VFD's DC bus overvoltage fault? Variable frequency drives (VFDs) are a crucial component in industrial automation, providing precise control over a motor's speed and torque. Any and all events that could cause a jump in DC bus voltage could lead to a dc link. When the motor's inertial feedback energy or power surge impacts the DC bus in the VFD system, if the voltage exceeds the safe range (typically >800V/480V system), the DC bus overvoltage protection is triggered.

    [PDF Version]
  • Current direction at relay protection fault point

    Current direction at relay protection fault point

    Consider a fault occurs at a point P. Hence the fault current flows from the generator G through the breaker A and E. Also the fault current comes from the breaker series A . This White Paper describes the sense, the potentials and the use of directional protection and directional zone selectivity functions, hereafter called “D” and “SdZ D” respectively. This selective operation helps avoid unnecessary tripping of circuit breakers and ensures that only the faulty section is isolated. Directional relays are not just overcurrent devices with extra logic. They compare current from CTs with voltage from PTs to determine the fault direction. I care. This practice-oriented paper shows, in addition to the illustrative explanation of the basis of ground fault parameters in insulated and arc-suppression-coil-ground systems, the connection variants for determination of the ground fault direction in detail.

    [PDF Version]

Critical Infrastructure Optical Insights

Need Reliable Optical Solutions for Critical Industries?

Contact us today for product inquiries, custom cable assemblies, or technical support